Company Logo

Send Email

Call Us: 08071681639

Nimbus Technologies
Nimbus Technologies
Nimbus Technologies
Nimbus Technologies
Home » Data Loggers & Data Acquisition System
Nimbus Technologies Nimbus Technologies

Data Loggers & Data Acquisition System



Dcon / Modbus Serial RS485 Analog & Digital I/O Modules

I 7017 Input Type +/-150mV, +/-500mV , +/-1V, +/-5V, +/-10V
+/-20mA (requires optional external 125 ohm resistor)
I 7018 Input Type +/-15mV, +/-50mV, +/-100mV, +/-500mV, +/-1V, +/-2.5V
+/-20mA (requires optional external 125 ohm resistor)
Thermocouple Type J, K, T, E, R, S, B, N, C
I 7013/33/15 Input Type RTD ( 1/3/6 channel)
Wire connection 2/3/4 wire
RTD Type Pt100 a=0.00385,  Pt100 a=0.003916,  Ni120,  Pt1000 a=0.00385
I 7016 2 ch strain guage input
Input Type +/-15mV, +/-50mV, +/-100mV,+/- 500mV , +/-1V,+/- 2.5V, +/- 20mA
Output Channels 1
Output Range 0 to +10V
Max Output Load 40mA
Accuracy +/-0.05% of FSR
Drift +/-50ppm/ °C
Output Impedance 12 Ohms
Isolation 3000 VDC
I 7021/22/24 Analog Data Acquisition system Output 1/2/4 channel
Output Type 0~20mA, 4~20mA, 0~5V, +/-5V, 0~10V, +/-10V
Resolution 14-bit
I 7041/51/52/52 14 / 16/ 8
Input Type Sink or Source,Isolated channel with common power or ground
I 7042/43/45 13/16
Output Type Isolation Open Collector
Output Voltage 30V max.
Output Current 100mA per channel, Direct drive power relay module
Isolation Voltage 3750V
I 7058/59 AC INPUT Module 8
Input Type AC, Differential, isolated
Off Voltage Level 30VAC max.
On Voltage Level 80 ~ 250VAC
AC Frequency 50~60Hz ( > 45Hz Min.)
Channels 7
I 7044/50/55D Digital I/O MODULE Source, non-isolated channel with common ground
Off Voltage Level +1V max.
On Voltage Level +4V ~ +30V
Input Impedance 3K9, 0.3W
Counters channels : 7
Max. Counters : 16-bit (65535) 
Max. Input Frequency : 100Hz
Min. Pulse Width : 5ms
Digital Data Acquisition system Output :
I 7044/50/55D Digital I/O MODULE 8
Output Type NPN, Source, Open collector
Output Voltage 30V max.
Output Current 30mA max.
I 7080/83 COUNTER I/O MODULE COUNTER / 3-axis
Input Type Isolated
Encoder Mode Quadrant counting mode, CW/CCW counting mode, Pulse/Dir counting mode
Isolation Voltage Input level 5V Logic High : 3.5V~5V
Logic Low :0V~2V
Logic High: 5V~12V
Input 12V with external resistor 1K ohm Logic Low :0V~2V
Input 24V with external resistor 2K ohm Logic High:7V~24V
Logic Low :0V~2V
Maximum Count 32bit
Maximum counting rate 1MHz

Nimbus Technologies Nimbus Technologies Nimbus Technologies
Nimbus Technologies Industrial Computer Chassis Nimbus Technologies
Nimbus Technologies Nimbus Technologies Nimbus Technologies
Nimbus Technologies Nimbus Technologies
Analog Input
Input Channels 1/ 8 differential or 6 differential and 2 single-ended by jumper select
Input Type +/-15mV, +/-50mV, +/-100mV,+/- 500mV , +/-1V,+/- 2.5V, +/- 20mA
Resolution 16-bit
Sampling Rate 10 Samples/ Second
Accuracy +/-0.1%
Band Width 15.7 Hz
Zero Drift 0.5uV/°C
Span Drift 25ppm/¢XC
Input Impedance 20M Ohms
Common Mode Rejection 150dB
Normal Mode Rejection 100dB
Over Voltage Protection +/-35V
Open Thermocouple Detection No
Photo-Isolation 3750 Vrms
Intra-module Isolation, Field to Logic 3000 VDC
Interface
Interface RS-485
Format N, 8, 1
Buad Rate 1200 ~ 115200bps
LED Display
1 LED as Power/ Communication indicator
Power
Input +10 to +30 Vdc
Power Consumption 1.0W
Environment
Operating temperature -25 to 75¢XC
Storage temperature -40 to 85¢XC
Humidity 5 to 95%, non-condensing
  Note: Above is common specification
Yes I'm Interested





Nimbus Technologies Nimbus Technologies


Modbus Analog / Digital I/O

Type
Model
Description
Analog Input Voltage & Current(Selection Guide) M-7017 M-7017RC Measure V, mV, mA
M-7017C M-7017R-A5
M-7017R M-7017Z
Thermocouple(Selection Guide) M-7011 M-7018R
M-7011D M-7018Z
RTD(Selection Guide M-7018 M-7019R
M-7015 M-7015P
M-7033 M-7033D Measure V, mV, mA, temperature (With thermocouple sensor)
Thermistor(Selection Guide) M-7005 Measure temperature with RTD  sensor
Strain Gauge(Selection Guide) M-7016 M-7016D Measure temperature with thermistor
Measure strain
Type
Model
Description
Analog Data Acquisition system Output(Selection Guide) M-7022 M-7024 Slew rate of AO channels are   programmable
Type
Model
Description
DC Digital Input(Selection Guide) M-7041 M-7052 DI channels can be used to get status  and low speed (100Hz Max.) counts
M-7041D
M-7051 M-7052D
M-7051D M-7053
M-7053D
DC Digital Data Acquisition system Output(Selection Guide) M-7045 M-7045D DC Output Module
DC Digital Input and Output(Selection Guide) M-7050 M-7055 DI channels can be used to get status  and low speed (100Hz Max.) counts
M-7050D M-7055D
Type
Model
Description
Power Relay Output(Selection Guide) M-7060 M-7060D Traditional Relay; Approx life-time:Mechanical: 20x10^6 OPSElectrical: 100x10^3 OPS Full Load
M-7065 M-7065D
M-7067 M-7067D
Type
Model
Description
Counter/Frequency(Selection Guide) M-7080 M-7080D Input signal range can be 1Hz to 100KHz
M-7080B M-7080BD
Yes I'm Interested





Nimbus Technologies Nimbus Technologies


Nimbus Technologies Nimbus Technologies Nimbus Technologies
Nimbus Technologies Single Board Computer Nimbus Technologies
Nimbus Technologies Nimbus Technologies Nimbus Technologies
Nimbus Technologies Nimbus Technologies

Programmable Datalogger SERS 951-D

  • 1/4 DIN size package.
  • Microprocessor based accuracy.
  • Alarm capabilities with relay outputs.
  • 8 ch, 16 ch, or 24 channel models.
  • AUTO / MANUAL mode facilities.
  • Addressable serial interface.
  • Retain set up during power loss.
  • Data storage for analysis using standard 80 columns printer.
  • Lower cost of ownership. Universal input, can be selected on site.
  • Memory available 8K, 16K & 32K.
  • Alarm relay board for 8 ch,16 ch,24 ch available.
  • Multidrop RS 485 connectivity.
  • Size: 96 x 96 x 120 mm.
Yes I'm Interested









Nimbus Technologies Nimbus Technologies



Universal Data Logger with Touch Screen LCD for 8/16 channel

DL-315

Data Logger is used for acquiring industrial process signals like RTD, Thermocouple, mV, V, mA, A etc. It can be used for displaying, storing and Alarm purpose. There are 8, 16, 32 channels Data Logger available.

This is used in following industries:
  • Heat Treatment/Furnace.
  • Cold Storage.
  • Pharmaceuticals.
  • Chemicals etc.

KEY FEATURES
  • 8/16/32 channel data logger.
  • Touchscreen.
  • Serial Comport.
  • Printer port – Direct Printing
  • A pair of relays is provided for Alarm purpose. (Relay 1-Low alarm, Relay 2-High alarm.)
  • A USB slot is provided for direct copying of data into USB drive.
  • The maximum data that can be obtained from a single channel of a sensor is 20,000 records.
Nimbus Technologies Nimbus Technologies Nimbus Technologies
Nimbus Technologies Universal Data Logger with Touch Screen LCD for 8/16 channel Nimbus Technologies
Nimbus Technologies Nimbus Technologies Nimbus Technologies
Nimbus Technologies Nimbus Technologies


Nimbus Technologies Nimbus Technologies


Nimbus Technologies Nimbus Technologies Nimbus Technologies
Nimbus Technologies Universal Data Logger With Touch Screen Lcd 8channel For Sms Alert & Cloud Communication Nimbus Technologies
Nimbus Technologies Nimbus Technologies Nimbus Technologies
Nimbus Technologies Nimbus Technologies

Universal Data Logger With Touch Screen Lcd 8channel For Sms Alert & Cloud Communication

By keeping track with the market development, we are involved in offering Universal Data Logger With Touch Screen Lcd 8channel For Sms Alert & Cloud Communication. Our offered product is manufactured using high end technology by our dexterous professionals. Moreover, our quality controllers conduct a series of tests on this product to ensure that the only defect free range is delivered.





Nimbus Technologies Nimbus Technologies


Nimbus Technologies Nimbus Technologies

Member IndiaMART.com© Nimbus Technologies,Thane. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited
Web Statistics

Looking for Product Name ?

x

Send SMS Enquiry

*Please Enter Requirment

*Please Enter valid Mobile Number

*Please Enter Proper Name