Modbus Gateway

Offering you a complete choice of products which include ethernet modbus gateway, modbus data logger, modbus iot gateway, modbus rtu to modbus tcp converter, tgw-718 modbus rs485 to modbus tcp convertor and modbus data concentrator.

Ethernet Modbus Gateway

Request Callback

₹ 15000 / Piece Get Latest Price

Product Brochure
Throughput100 Mbps
InterfaceRS 485
Serial Port Number1
Modbus TypeModbus RTU
Usage/ApplicationIOT
Model Name/NumberGW1101-1D(RS-485)
Compatible Brand3 One Data
ColorBlack
Ethernet Ports1 Port
Power Supply12 to 48VDC
Operating Temperature-40 degree C To 75 degree C
Baud Rate110 to 115200bps
Rtu InterfaceRS485/RS422
Operating System-40 degree C To 75 degree C
Weight0.3kg
Dimensions (W x H x D)97mmx110mmx25mm
Supports multiple protocolsModbus ASCII/ RTU/ Modbus TCP/IP
Configure ModeWEB configuration
IndicatorPower supply indicator,running indicator,Ethernet port indicator,serial port indicator
Installationwall mounting
MaterialIP40 protection,metal
CertificationCE,FCC,RoHS
Warrenty1 Year

Minimum order quantity: 1 Piece

GW1101-1D(RS-485)-TB-P(12-48VDC) is Modbus gateway designed for integrating Modbus RTU/ASCII and Modbus TCP networks; it can achieve the conversion between Modbus RTU/ASCII and Modbus TCP protocols. This product has 1 RS-485/422 serial port and 1 100M Ethernet copper port. It adopts wall mounting to meet the requirements of different application scenes.
Modbus gateway supports multiple network protocols, such as Modbus, TCP, IP, UDP, TELNET, ARP, ICMP, HTTP, HTTPS, SNMP, SSH,SMTP, SNTP,DNS and DHCP protocols. It possesses complete management function, and supports access control, rapid configuration, online upgrading, etc. RTU Master, RTU Slave, ASCII Master, ASCII Slave and other operating modes are supported; it supports up to 256 Modbus TCP client (master) accesses and connects up to 128 Modbus TCP server (slave) devices. TELNET, WEB, SSHD and other access modes are also supported. It can provide users with good experience with friendly design of network management system interface, simple and convenient operation.

Modbus Data Logger

Request Callback

₹ 45000 / Piece Get Latest Price

Product Brochure
Usage/ApplicationIndustrial
BrandICPDAS
Model Name/NumberMDCL-705i
Network Speed10/100
Number Of Ports/Pins1 ETHERNET,4 RS485
Operating Humidity99%
Output Voltage9-30V DC
Power SourceDC
Rated Voltage24
Size/Dimension97 x 120 x 42 (W x L x H)
Model No-MDCL-705i

Minimum order quantity: 1 Piece

Features
  • Support Modbus master/slave
  • Supports up to 8 simultaneous Modbus TCP connections
  • Up to 250 sets of Modbus RTU commands and built-in 9600 Modbus data registers
  • Support CSV (Comma-Separated Values) file configuration, easy to use and maintain
  • Built-in microSD memory card for storing Modbus data records
  • Each data can contain 120 parameters
  • The data record can support the ratio conversion function, which converts the original Modbus data into actual engineering units
  • Isolated RS-485 with 2500 VDC isolation voltage protection
Introduction
The Modbus Data Concentrator is the ideal product for IIoT system integrators. The MDCL-705i is used to collect and store data from multiple Modbus slave devices over the serial communication interface and make the data available to back-end management system via Ethernet communication. In this way, conventional devices can be attached to a modern control system and through the Modbus TCP protocol easily communicates with most SCADA / HMI systems and PLCs. Thus the management system can poll the MDCL-705i for the data from several Modbus devices at once; making the process much more efficient.
The MDCL-705i can help you build a cost-effective data acquisition solution for reading real-time data from meters, sensors and more. The ability to integrate with SCADA systems and other industrial devices, and the reliable real-time data collection in combination with the data logger makes MDCL-705i one of the most cost-effective products of IIoT.

Data Logger
Data TypeBoolean, 16-bit Integer, 32-bit Integer and 32-bit Floating
Max. Recording Period per File1 hr, 2 hr, 6 hr, 12 hr, 24 hr
File Manager InterfaceBuilt-in web server
Storage Media32 GB microSD card
File FormatCSV
Time Interval5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min, 1 hr, 6 hr
Max. Records120 parameters per record
Display
Type5-Digit 7 Segment LED Display (display system information)
LED Indicators
Status1 x System, to (display heartbeat)
Ethernet
Ports10/100 Base-TX
ProtocolModbus/TCP slave, HTTP
Socket Connections8 Modbus/TCP
COM Ports
Ports2 x 2-wire RS-485 (non-isolated)
3 x 2-wire RS-485 (2.5 kV isolation protection)
Baud Rate1200, 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200 bps
Data FormatN81, E81, O81, N82, E82, O82
ProtocolModbus RTU Master/Modbus RTU Slave
Polling Definition250 definitions for all RS-485 ports
Shared Memory9600 registers for each of AI, AO, DI and DO data
Max. Connection32 slaves for each RS-485 port
Power
Input Range+10 ~ +48 VDC
Consumption2 W
Mechanical
CasingMetal
Dimensions (mm)97 x 120 x 42 (W x L x H)
InstallationDIN-Rail or Wall Mounting
Environment
Operating Temperature-25 ~ +75 °C
Storage Temperature-30 ~ +80 °C
Humidity10 ~ 90 % RH, Non-condensing

Modbus Iot Gateway

Request Callback

₹ 22000 / Piece Get Latest Price

Product Brochure
Terminator for RS-DB9 For RS232 and Screw Terminal for RS485/422
Usage/ApplicationIOT
Model Name/NumberNT-832-4-I-Modbus
Compatible BrandNimbus
Ethernet Ports1 Port
ColorNavy Blue
Power SupplyDC 9~32V
Operating Temperature-20 degree C to 70 degree C
Baud Rate300 bps ~ 230.4 K bps
Weight660 gm
Dimensions (W x H x D)195 * 120 * 35 mm ( W * D * H )
Country of OriginMade in India
CPUMT7688AN MIPS CPU
RAM128M Bytes
ROM32M Bytes Flash ROM
Ethernet Speed10 /100 Mbps
Communication ProtocolModbus RTU/ TCP Server / TCP Client
ProtectionBuilt-in 1.5KV Magnetic Isolation
Wi-Fi SupportYes
Data Rate11/54/72.2 Mbps @ 20Mhz Bandwidth
Frequency2.4GHz
DistanceUp to 50
SecurityLogin Password
Modbus Port4x RS232/422/485
UtilityBuilt-in Web server Setup, Easy Operation
CertificatesCE, FCC, ROHS
Warrenty1 Year

Minimum order quantity: 1 Piece

TCP to RTU support 8 simultaneous TCP Master, 32 simultaneous requests per Master.
 RTU to TCP support 8 TCP Slaves on each port.
 Software support :
TCP to RTU Slaves, RTU to TCP Slaves,
TCP to ASCII Slaves, ASCII to TCP Slaves
 Web Browser configuration
 Easy installation Windows utility
 On line F/W upgrade

Modbus RTU To Modbus TCP Converter

Request Callback

₹ 25000 / Piece Get Latest Price

Product Brochure
Terminator for RS-RS-232/RS-422/RS485
Dimensions (with ears)180 * 110 * 30 mm ( W * D * H )
Usage/ApplicationIOT
Model Name/NumberNT-832-2-MODBUS
Compatible Brandnimbus
ColorNavy Blue
Ethernet Ports1 Port
Power SupplyDC 9 to 32V,1000mA@12V,support DC Jack & Terminal Input
Operating Temperature-20 degree C to 70 degree C
Antenna2 dBi ; RP-SMA con
Baud Rate300 bps to 921.6kbps
Rtu InterfaceRS485
Weight460g
Dimensions (W x H x D)120 * 110 * 30 mm ( W * D * H)
Number Of Ports2
Country of OriginMade in India
CPUMT7688AN MIPS CPU,580 MHz
RAM128M Bytes DDR2 RAM
ROM32M Bytes Flash ROM
Ethernet10 /100 Mbps
ProtocolARP,IP,ICMP,UDP,TCP,HTTP,DHCP,DNS,MTP
ModeTCP Server / TCP Client / UDP
ProtectionBuilt-in 1.5KV Magnetic
HousingMetal
Wi-Fi SupportYes
Data Rate11/54/72.2 Mbps @ 20Mhz B
Frequency2.4GHz
Tx DistanceUp to 100m
SD InterfaceMicro SD Card

Minimum order quantity: 1 Piece

Ethernet - Port Type : RJ-45 Connector 
Speed : 10 /100 M bps ( Auto Detecting )  Protocol : ARP , IP , ICMP , UDP , TCP , HTTP , DHCP 
Protocol :PPPoE , DDNS , NTP , FTP , Telnet  Mode : TCP Server / TCP Client / UDP 
Protection : Built-in 1.5KV Magnetic Isolation.
WiFi port :  2.4G WiFi IEEE 802.11 b/g/n Support AP / Station
Serial Ports *2 
Port : RS – 232/422/485 * 2 Port ( RS-232 - RX/TX only ) 
Port : RS - 422 / 485 ( Surge Protect )  Speed:300 bps ~ 230.4 K bps  
RS-232 Pins : Rx , Tx , GND 
RS-422 : Rx+ , Rx- , Tx+ , Tx- ( Surge Protect) RS-485 : Data+ , Data- ( Surge Protect )  15KV ESD for all signals

TGW-718 Modbus RS485 to Modbus TCP Convertor

Request Callback

₹ 15000 / Piece Get Latest Price

Product Brochure
UsageNetworking
Dimension (W x H x D)222 x 122 x 35
Model Name/NumbertGW-718
Country of OriginMade in India
Frequency50 Hz

Minimum order quantity: 1 Piece

Features
  • Supports Modbus TCP/UDP master and slave
  • Supports Modbus RTU/ASCII master and slave
  • Max. TCP connections (masters) per serial port: 32
  • Read-cache ensures faster Modbus TCP/UDP response
  • Supports UDP responder for device discovery (UDP Search)
  • Static IP or DHCP network configuration
  • Tiny Web server for configuration (HTTP)
  • Allows automatic RS-485 direction control
  • Terminal block connector for easy wiring
  • Cost-effective Modbus gateway
Applications

CPU Module
CPU32-bit ARM
Ethernet
Ports10/100 Base-TX, 8-pin RJ-45 x 1, (Auto-negotiating, Auto-MDI/MDIX, LED indicator)
PoE (IEEE 802.3af, Class 1)
COM Ports
Ports1 x 3-wire RS-232/RS-485/RS-422
Baud Rate115200 bps Max.
Bias ResistorYes, 1 KΩ
ParityNone, Odd, Even, Mark, Space
Data Bit5, 6, 7, 8
Stop Bit1, 2
Node Address254 (max.)
Power
Consumption0.07 A @ 24 VDC
Powered from PoEIEEE 802.3af, Class 1
Powered from Terminal Block+12 ~ 48 VDC
Mechanical
CasingPlastic
Dimensions (mm)52 mm x 95 mm x 27 mm (W x H x D)
InstallationDIN-Rail Mounting
Environment
Operating Temperature-25 ~ +75 °C
Storage Temperature-30 ~ +80 °C
Humidity10 ~ 90% RH, non-condensing
  • tGW-712 CR/tGW-712i CR- Tiny Modbus/TCP to RTU/ASCII Gateway with PoE and 1-port RS-232 (RoHS)
  • tGW-722 CR/tGW-722i CR- Tiny Modbus/TCP to RTU/ASCII Gateway with PoE and 2-port RS-232 (RoHS)
  • tGW-732 CR/tGW-732i CR- Tiny Modbus/TCP to RTU/ASCII Gateway with PoE and 3-port RS-232(RoHS)
  • tGW-715 CR/tGW-715i CR- Tiny Modbus/TCP to RTU/ASCII Gateway with PoE and 1-port RS-422/485 (RoHS)
  • tGW-725 CR/tGW-725i CR- Tiny Modbus/TCP to RTU/ASCII Gateway with PoE and 2-port RS-485 (RoHS)
  • tGW-735 CR/tGW-735i CR- Tiny Modbus/TCP to RTU/ASCII Gateway with PoE and 3-port RS-485 (RoHS)
  • tGW-718 CR/tGW-718i CR- Tiny Modbus/TCP to RTU/ASCII Gateway with PoE and 1-port RS-232/422/485 (RoHS)
  • tGW-724 CR/tGW-724i CR- Tiny Modbus/TCP to RTU/ASCII Gateway with PoE, 1-port RS-232 and 1-port RS-485 (RoHS)
  • tGW-734 CR/tGW-734i CR- Tiny Modbus/TCP to RTU/ASCII Gateway with PoE, 2-port RS-232 and 1-port RS-485 (RoHS)
  • tGW-715-T CR tGW-715i-T CR- Tiny Modbus/TCP to RTU/ASCII Gateway with 1-port RS-422/485 (RoHS)
  • tGW-718-T CR tGW-718i-T CR- Tiny Modbus/TCP to RTU/ASCII Gateway with 1-port RS-232/422/485 (RoHS)

Modbus Data Concentrator

Request Callback

₹ 32000 / Piece Get Latest Price

Product Brochure
Model Name/NumberMDC-714
Easy configurationCSV file
Support forup to 8 Modbus TCP masters
Dimension102 mm x 125 mm x 28 mm
System LED IndicatorYes,to display heartbeat
InstallationWall Mount

Minimum order quantity: 1 Piece

Features
  • Supports Modbus master/slave on the serial port and Modbus TCP slave on the Ethernet interface
  • Supports up to 8 simultaneous Modbus TCP connections at one time
  • Data pool for up to 9600 registers
  • Modbus polling commands for up to 250 definitions
  • Easy configuration with a simple CSV file for quick start-up
  • HTML5 Web-based user interface
IntroductionMDC-700 series is a Modbus Data Concentrator that has ability to perform up to 250 Modbus/RTU commands to read/write from/to Modbus slave devices via RS-232/485 and allows up to 8 Modbus/TCP masters to get the polled data via the Ethernet. MDC-700 series provide a built-in web server to ease the configuring and provide clear information for the performed results of each Modbus/RTU command on the RS-232/485.

Modbus Data Concentrator
The MDC performs the pre-defined Modbus/RTU commands to read/write data from/to the Modbus/ RTU slave devices via the RS-232/485. It mirrors the data of the slave devices to its own shared memory. And it accepts up to 8 Modbus/TCP masters to directly read/write data form/to the shared memory instead of polling each Modbus/RTU slave device one by one. This way not only makes the data on the RS-232/485 sharable to multiple Modbus/TCP master but also shorten the time to read/write data from/to multiple Modbus/RTU slave devices.

Display
Type 5 x Digit 7 Segment LED Display
LED Indicators
Status 1 x System, to display heart beat
Ethernet
Ports x1, 10/100 Base-TX
Protocol Modbus/TCP Slave
COM Ports
Ports 1 x 5-wire RS-232
4 x 2-wire RS-485
Baud Rate 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
Data Format N81, E81, O81
Protocol Modbus RTU Master/Modbus RTU Slave
Polling Definition 250 definitions for all RS-232/485 ports
Shared Memory 9600 registers for each of AI, AO, DI and DO data
Power
Input Range +10 VDC ~ +30 VDC (non-regulated)
Consumption 2.5 W
Mechanical
Casing Metal
Dimensions (mm) 102 mm x 125 mm x 28 mm (W x H x D)
Installation Wall Mounting
Environment
Operating Temperature -25 ~ +75 °C
Storage Temperature -30 ~ +80 °C
Humidity 10 ~ 90% RH, non-condensing
X

Contact Us

R. Krishnan (CEO)
Nimbus Technologies
Plot No. C-9 Unit No 225, Globe Estate, Midc Phase, Dombivli East, Kalyan - 421203, Thane, Maharashtra, India

Get Directions
Send Email
Share: