Profinet Modules

Prominent & Leading Exporter from Kalyan, we offer modbus to profinet converter and profinet to modbus tcp gateway.

Modbus To Profinet Converter

Request Callback

₹ 38000 / Piece Get Latest Price

Product Brochure
MaterialPlastic
Usage/ApplicationIndustrial
Product TypeDigital, Profinet
operating temperatures between-25 to 75 degree
Power supply10 to 30 V DC

Minimum order quantity: 1 Piece

Features
  • Protocol: PROFINET IO Device
  • PROFINET Conformance Class B and RT Class 1
  • Cyclic Time: 1ms (min)
  • Generic GSDML File Provided (Version 2.25)
  • Max length of input/output data is 512/512 Bytes
  • Support Modbus Master and Slave mode
  • Support Modbus RTU and ASCII format
  • 4 kV Contact ESD protection for any terminal
Introduction

The GW-7662 specially designed for PROFINET IO device. It allows PROFINET controller to access Modbus devices. These Modbus devices maybe a PLC, a sensor, ICPDAS M-7000 series modules and so forth. We also provide a utility software for users to configure GW-7662. By using this module, users can put their Modbus devices into PROFINET network easily.

CPU Module
CPU 32-bit CPU Core
EEPROM 8 KB
Flash 4 MB
SRAM 32 MB
Watchdog Timer CPU built-in
LED Indicators
Status AP LED, BOOT LED, ERR LED
Ethernet
Services ICMP, IGMP, ARP, DHCP, TELNET, TFTP, SNMP, VLAN Priority Tagging
COM Ports
Ports RS-232/RS-422/RS-485 (can't be used simultaneously)
3-pin screwed terminal block (RxD, TxD, GND)
4-pin screwed terminal block (RxD+, RxD-, TxD+, TxD-)
2-pin screwed terminal block (DATA+, DATA-)
Baud Rate 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400, 460800
Parity None, Even, Odd
Data Bit 7, 8
Stop Bit 1, 2
PROFINET
Conformance Classes Class B
Services RTC, RTA, CL-RPC, DCP, LLDP, I&M
Cycle Time 1 ms (min)
Protocol PROFINET IO Device
Power
Consumption 3.4 W
Mechanical
Dimensions (mm) 42 x 76 x 119 (W x L x H)
Installation DIN-Rail
Environment
Operating Temperature -25 ~ +75 ℃
Storage Temperature -30 ~ +80 ℃
Humidity 10 ~ 90% RH, Non-condensing

PROFINET To Modbus TCP Gateway

Request Callback

₹ 38000 / Piece Get Latest Price

Product Brochure
Usage/ApplicationIndustrial
Model Name/NumberGW-7663
Dimensions42 x 76 x 110 (W x L x H)
InstallationDIN-Rail
Consumption3.4 W

Minimum order quantity: 1 Piece

Features
  • Protocol: PROFINET IO Device
  • PROFINET Conformance Class B and RT Class 1
  • Cyclic Time: 1ms (min)
  • Generic GSDML File Provided (Version 2.25)
  • Max length of input/output data is 512/512 Bytes
  • Support Modbus Master and Slave mode
  • 4 kV Contact ESD protection for any terminal
Introduction

The GW-7663 specially designed for PROFINET IO device. It allows PROFINET controller to access Modbus TCP devices. These Modbus devices maybe a PLC, a sensor, ICPDAS I-8KE4-MCTP, ET-7000 series modules and so forth. We also provide a utility software for users to configure GW-7663. By using this module, users can put their Modbus devices into PROFINET network easily.

CPU Module
CPU 32-bit CPU Core
EEPROM 8 KB
Flash 4 MB
SRAM 32 MB
Watchdog Timer CPU built-in
LED Indicators
Status AP LED, BOOT LED, ERR LED
Ethernet
Services ICMP, IGMP, ARP, DHCP, TELNET, TFTP, SNMP, VLAN Priority Tagging
PROFINET
Conformance Classes Class B
Services RTC, RTA, CL-RPC, DCP, LLDP, I&M
Cycle Time 1 ms (min)
Protocol PROFINET IO Device
Power
Consumption 3.4 W
Mechanical
Dimensions (mm) 42 x 76 x 110 (W x L x H)
Installation DIN-Rail

 

Environment
Operating Temperature -25 ~ +75 ℃
Storage Temperature -30 ~ +80 ℃
Humidity 10 ~ 90% RH, Non-condensing
X

Contact Us

R. Krishnan (CEO)
Nimbus Technologies
Plot No. C-9 Unit No 225, Globe Estate, Midc Phase, Dombivli East, Kalyan - 421203, Thane, Maharashtra, India

Get Directions
Send Email
Share: